Measurements by the relative method using the germanium detector for radionuclides

Authors

  • Maria Candida Moreira de Almeida
  • Ronaldo Lins da Silva
  • José Ubiratan Delgado

DOI:

https://doi.org/10.34117/bjdv11n7-031

Keywords:

germanium detector, radionuclides, relative method, metrology

Abstract

The National Laboratory for Ionizing Radiation Metrology (LNMRI/IRD/CNEN) of Rio de Janeiro performed standardization of different radionuclides. Such standards are applied in nuclear industries, nuclear research, radiation protection and nuclear medicine.  The comparative method using a Ge detector was applied for obtaining results of some radioactive point and ampoule sources. The activities of 22Na, 60Co, 133Ba and 137Cs radionuclides were determined. The total uncertainties reached values below 1.0 % to liquid samples and below 1.4% to solid samples, in a confidence level of 68 %.

References

M.C. Lépy , A. Pearce, O. Sima, Uncertainties in gamma-ray spectrometry, Bureau International des Poids et Mesures, Metrologia, 2015, 52, pp.123.

S. Mancini, S. A. Pehlivanoglu, N. Todorovic, S. Ozden, M. Guida, Radiological characterization of materials used in Italian heritage buildings, Acta IMEKO, 2024, 13 (3), pp.1-5.

M.A.L. Silva, M.C.M. de Almeida, J.U. Delgado, Half-life of radionuclides determined by the reference source method. Journal of Radioanalytical and Nuclear Chemistry, 2005, 264, (3) pp.571.

T.Vidmar, M. Korun, Calculation of LS-curvs for coincidence summing corrections in gamma-ray spectrometry, Nuclear Instruments and Methods in Physics Research A, 2006, 556(2), pp.543-546..

P. Jodlowski, S.J. Kalita, Gamma-ray spectrometry laboratory for high precision

measurements of radionuclide concentratios in environmental samples, Nukleonika, 2010, 55 (2) pp.143.

H.M. Diab, HPGe detector efficiency curve evaluation for low-level measurements, Arab Journal of Nuclear Science and Applications, 2015, 48 (4), pp. 53.

UTFPR , Produção de Radioisótopos IPEN/SP, 2018 , MedNuc_Aula_07.

M.M.Be , V.Chiste, C. Dulieu, E. Browne, V.Chechev, N. Kuzmenko, R. Helmer, A.Nichols, E.Schonfeld, R. Dersch, R., Table of Radionuclides, Sèvre, BIPM-5, 2012.

M.C.M. de Almeida, J.U.Delgado, R.L. Silva, R.Poledna , R.S. Gomes, A.L. Ferreira Filho, Uncertainty evaluation in activity measurements with HPGe using two relative methods, Brazilian Journal of Radiation Sciences 2022, 10(4), pp. 1–13.

G. Eleftherion, C. Tsabaris, E.G. Andraulakaki, F.K. Pappa, D.L. Patiris, High resolution gamma-ray spectrometry for routine measurements of environmental samples, Applied Radiation and Isotopes , 2024, 206, pp.111234.

P. Malfrait, J. Bobin, A.V. Ott,, Spectral in mixing of multi-temporal data in gamma-ray spectrometry, Nuclear Instruments and Methods in Phisics Research A, 2023, 1045, pp. 167547.

Downloads

Published

2025-07-14

How to Cite

Almeida, M. C. M. de, Silva, R. L. da, & Delgado, J. U. (2025). Measurements by the relative method using the germanium detector for radionuclides. Brazilian Journal of Development, 11(7), e80954. https://doi.org/10.34117/bjdv11n7-031

Issue

Section

Original Papers