Design and validation of a piezoelectric diaphragm micropump for drug delivery

Authors

  • Mauricio Calderon Zamora
  • Claudia Reyes Betanzo

DOI:

https://doi.org/10.34117/bjdv10n4-057

Keywords:

micropump, diaphragm, piezoelectric, drug delivery, zinc oxide

Abstract

There is a common eye ailment called Dry Eye Disease (DED) that causes symptoms of discomfort, visual disturbance, and tear film instability, which cause damage to the ocular surface. For treatment of this illness, the application of artificial tear fluid is usually prescribed. This work presents the design process of a piezoelectric micropump to become part of an automatic pumping system for delivering artificial tear fluid to people suffering from DED. Low polarizing voltage, portability, and achieving a variable output flow rate in the range of 1 µl/min, which is the necessary range needed by a person suffering from DED, are the focus of this design. Standard microfabrication techniques widely used in the CMOS industry and for MEMS development will be used for manufacturing the proposed micropump. For this reason, the materials and manufacturing processes involved must be CMOS-compliant. For the piezoelectric actuator, zinc oxide (ZnO) was selected due to its compatibility with CMOS technology and because it is readily available in thin film form through a sputtering process. Other materials involved in the device are silicon and aluminum. The design was validated through finite element analysis software, COMSOL Multiphysics®. The maximum flow rate obtained by a single micropump device was 2.51µl/min operating at 20V peak with a frequency of 900Hz. Also, the flow rate is controllable through variations in frequency, thus making it suitable for the application previously described.

References

AIRES SAMPAIO, R. M.; AIRES MONTENEGRO, A.B.; DE ANDRADE, C. R. Artificial tears in the treatment of dry eye disease: a literature review. Brazilian Journal of Development, v. 7, n. 7, p. 65512–65533, 2021.

https://doi.org/10.3411/bjdv7n7-024

CERRETANI, C. F.; RADKE, C. J. Tear Dynamics in Healthy and Dry Eyes. Current Eye Research, v. 39, n. 6, p. 580–595, 2014. https://doi.org/10.3109/02713683.2013.859274

GAYTON, J. L. Etiology, prevalence, and treatment of dry eye disease. Clinical Ophthalmology, v. 3, p. 405–412, 2009. https://doi.org/10.2147/OPTH.S5555

GERMAN, E. J.; HURST, M. A.; WOOD, D. Reliability of drop size from multi-dose eye drop bottles: is it cause for concern? Eye, v. 13, n. 1, p. 93–100, 1999. https://doi.org/10.1038/eye.1999.17

GRAUE-HERNÁNDEZ, E. O. et al. Dry eye symptoms and associated risk factors among adults aged 50 or more years in Central Mexico. Salud Pública de México, v. 60, n. 5, p. 520–527, 2018. https://doi.org/10.21149/9024

GROSS, H.; BLECHINGER, F.; ACHTNER, B. Human Eye. Em: Handbook of Optical Systems. [s.l: s.n.]. p. 1–87, 2008. https://doi.org/10.1002/9783527699247.ch1

JOSHITHA, C.; SREEJA, B. S.; RADHA, S. A review on micropumps for drug delivery system. 2017 International Conference on Wireless Communications, Signal Processing and Networking (WiSPNET), 2017. https://doi.org/10.1109/WiSPNET.2017.8299745

KOSSIAKOFF, A. et al. Systems Engineering Principles and Practice. Second Edition. Wiley, 2011. https://doi.org/10.1002/9781119516699.ch3

LEE, H. J. et al. MEMS devices for drug delivery. Advanced Drug Delivery Reviews, v. 128, p. 132–147, 2018. https://doi.org/10.1016/j.addr.2017.11.003

MATTOS FERNANDES, A. C. et al. Prevalence of signs and symptoms of dry eye in patients with Glaucoma in a reference service in Pará. Brazilian Journal of Health Review, v. 6, n. 2, p. 5095–5113, 2023.

https://doi.org/10.34119/bjhrv6n2-050

MENI-BABAKIDI, N. et al. Control system applied to the microinjection of artificial tears for severe dry eye treatment. Applied Sciences (Switzerland), v. 10, n. 5, 2020. https://doi.org/10.3390/app10051883

MOHITH, S.; KARANTH, P. N.; KULKARNI, S. M. Recent trends in mechanical micropumps and their applications: A review. Mechatronics, v. 60, p. 34–55, 2019. https://doi.org/10.1016/j.mechatronics.2019.04.009

MURUBE, J. et al. Subcutaneous abdominal artificial tears pump-reservoir for severe dry eye. Orbit, v. 22, n. 1, p. 29–40, 2003. https://doi.org/10.1076/orbi.22.1.29.14012

O’BRIEN, P. D.; COLLUM, L. M. T. Dry eye: Diagnosis and current treatment strategies. Current Allergy and Asthma Reports, v. 4, n. 4, p. 314–319, 2004. https://doi.org/10.1007/s11882-004-0077-2

PILLAY, V.; CHOONARA, Y. E.; DU TOIT, L. C. Intraocular Drug Delivery Technologies: Advancing Treatment of Posterior Segment Disorders of the Eye. In: PATHAK, Y. et al. Nano-Biomaterials For Ophthalmic Drug Delivery. Cham: Springer International Publishing, p. 407–460, 2016. https://doi.org/10.1007/978-3-319-29346-2_18

SEFTON, M. V; BURNS, K. J. Controlled release micropumping of insulin at variable rates. Industrial & Engineering Chemistry Product Research and Development, v. 20, n. 1, p. 1–5, 1981. https://doi.org/10.1021/i300001a001

SHAWGO, R. S. et al. BioMEMS for drug delivery. Current Opinion in Solid State and Materials Science, v. 6, n. 4, p. 329–334, 2002. https://doi.org/10.1016/S1359-0286(02)00032-3

The Definition and Classification of Dry Eye Disease: Report of the Definition and Classification Subcommittee of the International Dry Eye Workshop (2007). The Ocular Surface, v. 5, n. 2, p. 75–92, 2007. https://doi.org/10.1016/S1542-0124(12)70081-2

VAN LINTEL, H. T. G.; VAN DE POL, F. C. M.; BOUWSTRA, S. A piezoelectric micropump based on micromachining of silicon. Sensors and Actuators, v. 15, n. 2, p. 153–167, 1988. https://doi.org/10.1016/0250-6874(88)87005-7

VARGASON, A. M.; ANSELMO, A. C.; MITRAGOTRI, S. The evolution of commercial drug delivery technologies. Nature Biomedical Engineering, v. 5, n. 9, p. 951–967, 2021. https://doi.org/10.1038/s41551-021-00698-w

Downloads

Published

2024-04-23

How to Cite

Zamora, M. C., & Betanzo, C. R. (2024). Design and validation of a piezoelectric diaphragm micropump for drug delivery. Brazilian Journal of Development, 10(4), e69134. https://doi.org/10.34117/bjdv10n4-057

Issue

Section

Original Papers