Secondar neutrons induced from a medical proton accelerator in a water phantom

Authors

  • Nguyễn Khắc Sơn
  • Võ Hồng Hải
  • Trần Ngọc Tiến Phát
  • Trần Công Thiện

DOI:

https://doi.org/10.34117/bjdv10n4-049

Keywords:

neutron, medical proton accelerator, pulse shape discrimination, stilbene scintillation detector

Abstract

This study investigates the production of radiation-induced secondary neutrons resulting from the irradiation of a water phantom by a medical proton accelerator. Measurements were conducted using a 2-inch by 2-inch stilbene scintillation detector. To distinguish between neutrons and the gamma background, we applied a pulse shape discrimination technique utilizing the charge integration ratio (Qratio) method. Our analysis carries out for three proton beam energies: 76 MeV, 80 MeV, and 132 MeV. The findings demonstrate the feasibility of using a stilbene scintillator detector in conjunction with the Qratio method for the measurement and analysis of secondary neutrons, which are detectable in significant quantities.

References

Newhauser WD, Zhang R (2015). The physics of proton therapy. Physics in Medicine & Biology. 2015;24;60(8): R155.

David J. Brenner, Eric J. Hall (2008). Secondary neutrons in clinical proton radiotherapy: A charged issue. Radiotherapy and Oncology 86 (2008) 165–170.

Uwe Schneider and Roger Hälg (2015). The impact of neutrons in clinical proton therapy. Radiation Oncology, a section of the journal Frontiers in Oncology.

Byoung-Hwi Kang, Seung-Kyu Lee, Yong-Kyun Kim, N.Z. Galunov and Gi-Dong Kim (2010), Evaluation of a Composite Stilbene for the Fast Neutron Detection. IEEE Nuclear Science Symposium & Medical Imaging Conference.

Scott D. Ambers, Member, Lu Huang, Marek Flaska, Member, and Sara A. Pozzi, Member (2010), Reference-Pulses Neutron/Gamma-Ray Pulse Shape Discrimination in Liquid Scintillators for Deposited Neutron Energies from 200 keV. IEEE Nuclear Science Symposium & Medical Imaging Conference.

Chanho Kim, Jung-Yeol Yeom, Geehyun Kim (2019). Digital n-γ Pulse Shape Discrimination in Organic Scintillators with a High-Speed Digitizer. Journal of Radiation Protection and Research 2019;44(2):53-63

Asma Parveen I. Siddavatam (2014), Methods of Pulse Shape Discrimination (PSD), International Journal of Application or Innovation in Engineering & Management (IJAIEM), Mumbai India.

S.A Pozzi*, M.M. Bourne, S.D. Clarke (2013), Pulse shape discrimination in the plastic scintillator EJ-299-33, Nuclear Instruments and Methods in Physics Research A.

Application note. Scintinel™ stilbene for fast neutron detection. Inrad Optic Comp. https://www.inradoptics.com/

PXI-5152 Specifications. National Instruments Corp. https://www.ni.com/docs/en-US/bundle/pxi-5152-specs/page/specs.html

Downloads

Published

2024-04-22

How to Cite

Sơn, N. K., Hải, V. H., Phát, T. N. T., & Thiện, T. C. (2024). Secondar neutrons induced from a medical proton accelerator in a water phantom . Brazilian Journal of Development, 10(4), e69092 . https://doi.org/10.34117/bjdv10n4-049

Issue

Section

Original Papers