Phantom comparison for MRI quality control tests according to manufacturers and national standards
DOI:
https://doi.org/10.34117/bjdv9n2-025Keywords:
magnetic resonance imaging, quality control, security resonance magneticAbstract
Quality control tests are mandatory and essential to monitor Magnetic Resonance Imaging equipment. These assist in determining improper functioning or parameters below established reference levels. The objective of this study was to perform quality control tests in magnetic resonance imaging equipment and to compare their methodology with both FLUKE and KONEX phantoms. Different protocols were used for their evaluation, including the American Association of Physics in Medicine, the American College of Radiologists, and the Brazilian National Health Surveillance Agency. In this study, we demonstrated the results for the most critical tests: slice thickness accuracy, slice position accuracy, high-contrast spatial resolution, low-contrast resolution, magnetic field, and slice thickness uniformity. The results are that, although both phantom objects are efficient for carrying out the tests required in Brazilian regulations, the KONEX phantom consumes less time, as it requires less to image all its structures. The FLUKE phantoms need a longer acquisition time to obtain all test structures and object images. Nevertheless, the results obtained in both are within limits required by Brazilian regulations and limits suggested by the manufacturers' manuals. This work is expected to be a basis for other physicians and services using similar phantoms.
References
JACKSON, E. F.; BRONSKILL, M. J.; DROST, D. J.; OCH, J.; POOLEY, R. A.; SOBOL, W. T.; CLARKE G. D. Acceptance testing and quality assurance procedures for magnetic resonance imaging facilities. American Association of Physicists in Medicine; 2010. DOI: https://doi.org/10.37206/101
American College of Radiology. Phantom Test Guidance for Use of the ACR Accreditation Program. Reston (VA), USA; 2005.
National Electrical Manufacturers Association - NEMA. Determination of Signal-to-Noise Ratio (SNR) in Diagnostic Magnetic Resonance Imaging; 2021.
Agência Nacional de Vigilância Sanitária (Brasil). Resolução Diretoria Colegiada nº611, de 09 de março de 2022. Diário Oficial da União, 09 março 2022; Seção 1.
Agência Nacional de Vigilância Sanitária (Brasil). Instrução Normativa nº 97, de 27 de maio de 2021. Requisitos sanitários para a garantia da qualidade e da segurança em sistemas de Ressonância Magnética e outras providências. Diário Oficial da União 31 maio 2021; Seção 1.
FLUKE Biomedical. Nuclear Associates 76-903 and 76-904 - AAPM MRI Phantoms. Revisão 2. User's manual nº 38616. 2005.
FLUKE Biomedical. Nuclear Associates 76-907 and 76-908 - AAPM MRI Phantoms. Revisão 3. User's manual nº 76-904-1. 2005.
American College of Radiology. Protocols for MRI. Available at: <https://www.acr.org/Practice-Management-Quality-Informatics/Quality-Care-News/Newsletter/Quality-and-Safety-eNews-December-2021/MR-Medium-Phantom-Update>. Last accessed: 19 Nov. 2022.
RASBAND, W. S. ImageJ, U. S. National Institutes of Health. Bethesda, Maryland, USA. 2011. Available at: <http://imagej.nih.gov/ij/>. Last accessed: 12 Nov. 2022.
DE CASTRO, A. R., MARTINS, C. C., JUNIOR, L. G. N., & DE CASTRO, J. D. V. Magnetic resonance imaging (mri) for parsonage turner syndrome Ressonância magnética (ressonância magnética) para a síndrome do virador do presbitério. Brazilian Journal of Development, v. 8, n. 1, p. 3875-3881, 2022.
SANTOS DAMASCENO, S., TOZZI, A. C. E., FERNANDES, A. J. F., COSTA, B. D. S., DE OLIVEIRA CARVALHO, G., MENDONÇA, I. P., ESTEVES, R. A Colecistectomia Videolaparoscópica: abordagem técnica, indicações para o tratamento de Colecistite calculosa e prováveis complicações/Videolaparoscopic cholecystectomy: technical approach, indications for the treatment of calculosa Cholecystitis and possible complications: Videolaparoscopic cholecystectomy: technical approach, indications for the treatment of calculosa Cholecystitis and possible complications. Brazilian Journal of Development, v. 8, n. 7, p. 52464-52483, 2022.
CAMPOS, B. M. ACR analysis performed with ACR Tester Software UNICAMP. Utilized in 2022.
CAPAVERDE, A. S.; MOURA, C. S.; DA SILVA, A. M. M. Desenvolvimento de um programa de controle de qualidade em ressonância magnética baseado nas recomendações do Colégio Americano de Radiologia. Rev. Bras. Fís. Méd., v. 6, n. 2, p. 79-85, 2012. DOI: https://doi.org/10.29384/rbfm.2012.v6.n2.p79-85.
MAZZOLA, A. A.; HERDADE, S. B.; KOCH, H. A.; CARVALHO, A. C. P. Protocolo de testes de aceitação em equipamentos de imagem por ressonância magnética. Radiol. Bras., v. 38, p. 195-204, 2005. DOI: https://doi.org/10.1590/S0100-39842005000300008.
RAMOS, J. E.; KIM, H. Y.; TANCREDI, F. Automation of the ACR MRI low-contrast resolution test using machine learning. In: IEEE. 2018 11th International Congress on Image and Signal Processing, BioMedical Engineering and Informatics (CISP-BMEI). [S.l.], 2018. p. 1–6. DOI: 10.1109/CISP-BMEI.2018.8633140.
IHALAINEN, T. M.; LÖNNROTH, N. T.; PELTONEN, J. I.; UUSI-SIMOLA, J. K.; TIMONEN, M. H.; KUUSELA, L. J.; SIPILÄ, O. E. MRI quality assurance using the ACR phantom in a multi-unit imaging center. Acta oncol, v. 50, n. 6, p. 966-972, 2011. DOI: https://doi.org/10.3109/0284186X.2011.582515.