Characterization of porous biomaterials of 316L stainless steel made from polyethylene waxes as pore-forming agents
Caracterização de biomateriais de aço inox 316L obtidos utilizando cera de polietileno como agente porogênico
DOI:
https://doi.org/10.34117/bjdv8n10-234Keywords:
biomaterials, 316L stainless steel, polyethylene, sinteringAbstract
For biomedical purposes, the 316L stainless steel has been used due to its high mechanical strength and its biotolerability by the human body. Its porosity allows the growth of living tissue within the implant, which improves fixation to hard tissues. Porous 316L stainless steel specimens were produced by powder metallurgy with controlled porosity by the addition of different polyethylene waxes granulometries (50 and 100 mm) and concentrations (0.0, 1.0, 2.0, 3.0 and 4.0%). The elastic modulus, porous morphologies and densities of the steel samples were determined. Thus, the densities and the elastic modulus were evaluated statistically through Tukey’s test. The results showed that the porosity increases proportionally to polyethylene wax concentration, but the elastic modulus decreases. The Tukey’s Test showed that there are no significant differences in most samples using the two waxes at most concentrations. Range values of 1.89 to 1.51 GPa using wax with 50 mm, and 1.72 to 1.19 GPa were respectively obtained using 100 mm particle size. The highest pore size (45 mm) and the lowest elastic modulus (1.19 GPa) were obtained by use of 4.0% of wax.
References
Orefice R.L., Pereira M. M., Mansur H.S., Biomateriais: Fundamentos e Aplicações, Guanabara Koogan, Rio de Janeiro, 2012.
Zou J.P., Ruan J.M., Physicochemical properties and microstructure of hydroxyapatite-316L stainless steel biomaterials, J. Centr. South Univ. Technol. 2004; 11: 113-118.
Heimke G., Biomechanical aspects of joint and tooth replacements. In: D.L. Wise, D.J. Trantolo, D.E. Altobelli (Eds.), Encyclopedic Handbook of Biomaterials and Bioengineering, Marcel Dekker, New York, 1995, 43-68.
Zanin M.S, Rigo E.C.S, Boschi A.O., Recobrimento biomimético de hidroxiapatita com pré-tratamento álcali-térmico sobre aços inoxidáveis austeníticos, Rev. Bras. Eng. Biom. 2007; 23: 117-122.
Cao W., Hench L.L., Bioactive materials, J. Ceram. Int. 1996; 22: 493-507.
Jones A.C., Arns C.H., Sheppard A.P, Hutmacher D.W., Milthorpe B.K., Knackstedt M.A., Assessment of bone ingrowth into porous biomaterials using micro-CT, Biomaterials. 2007; 28: 2491-2504.
Otsuki B., Takemoto M., Fujibayashi S., Neo M., Kokubo T., Nakamura T., Pore throat size and connectivity determine bone and tissue ingrowth into porous implants: three-dimensional micro-CT based structural analyses of porous bioactive titanium implants, Biomaterials. 2006; 27: 5892–5900.
Itala A.I., Ylanen H.O., Ekholm C., Karlsson K.H., Aro H.T., Pore diameter of more than 100 micron is not requisite for bone in growth in rabbits, J. Biomed. Mater. Res.2001; 58: 679-683.
Brito F.I.G., Medeiros K.F., Lourenço J.M., Um estudo teórico sobre a sinterização na metalurgia do pó, Holos. 2007; 3: 204-211.
Dewidar M.M., Yoon H.C., Lim J.K., Mechanical properties of metals for biomedical applications using, Powder metallurgy process: a review, Met. Mater. Int. 2006; 12: 193-206.