Efeito da aplicação prolongada do sistema adesivo convencional de 2 passos na qualidade de restaurações de resina composta em lesões cervicais não cariosas: Ensaio clínico controlado, randomizado, duplo cego / Effect of the extended time of application of the conventional two-step adhesive system on the longevity of composite resin restorations in non-carious cervical lesions: a double-blind randomized clinical trial

Authors

  • Márcio Neves Camargo
  • Leonardo de Almeida
  • Rafael Ferreira Scheffer
  • Camila Basso Alpini
  • Alessandro Dourado Loguercio
  • Viviane Hass
  • Fabiana Scarparo Naufel
  • Eloisa Andrade de Paula

DOI:

https://doi.org/10.34117/bjdv6n8-709

Keywords:

Adesivo dentinário, Restauração dentária, Ensaios clínicos aleatórios.

Abstract

Objetivo: Este ensaio clínico randomizado duplo-cego avalia a influência do aumento do tempo de aplicação em dois sistemas adesivos de duas etapas de etch-and-rinse (Peak® Universal Bond (P); Ultradent Products Ind e Single Link (SL); Angelus Dental Products Industry) aplicados em lesões cervicais não cariocas (NCCLs). Métodos: Um total de 119 restaurações foram colocadas aleatoriamente em 35 pacientes, de acordo com os seguintes grupos: P1 - aplicado de acordo com o fabricante; P2X - aplicado pelo tempo duplo; SL1 e SL2X (o mesmo modo de aplicação). O composto de resina Amelogen (Ultradent) foi colocado de forma incremental. As restaurações foram avaliadas imediatamente (linha de base) e 6 meses, usando os critérios FDI e USPHS. As análises estatísticas foram realizadas utilizando testes apropriados (=0,05). Resultados: Vinte e quatro restaurações foram perdidas aos 6 meses (4 para P1, 2 para P2X, 9 para SL1 e 9 para SL2X) (p < 0,05 entre grupos). A sensibilidade pós-operatória não foi observada em nenhum dos períodos de recall. Foram consideradas cinco restaurações com pequenas discrepâncias na adaptação marginal no recall de 6 meses usando os critérios de IDE (8 para P1, 7 para P2X, 12 para SL1 e 8 para SL2X; p > 0,05 entre os grupos). Dez restaurações foram consideradas como tendo pequenas discrepâncias na descoloração marginal no recall de 6 meses (2 para P1, 1 para P2X, 3 para SL1 e 2 para SL2X; p > 0,05 entre os grupos). Conclusão: O aumento do tempo de aplicação do sistema adesivo em duas etapas não melhorou o comportamento clínico das restaurações compostas colocadas nos NCCLs. Entretanto, o comportamento clínico pode ser influenciado pela composição dos sistemas adesivos.

References

De Munk J, Van Landuyt K, Peumans M, Poitevin A, Lambrechts P, Braem M, et al. A critical review of the durability of adhesion to tooth tissue: methods and results. J Dent Res. Feb 2005(84):118-135.

Ferreira SQ, Ferreira da Costa TR, Klein-Junior, CA, Accorente MªLR, Meier MM, Loguercio AD et al. Improvement of exposure time: Effect on adhesive properties and resin-dentin bond strengths of etch-and-rinse adhesives. J Adhes Dent 2011(3):235-241.

Reis A, Cardoso PC, Vieira LCC, Baratieri LN, Grande RHM, Loguercio AD. Effect of prolonged application times on the durability of resin-dentin bonds. J Dent Mat 2008(24):639-644.

Wilder AD Jr, Swift EJ Jr, May KN Jr, Wanddell SL. Bond strengths of conventional and simplified bonding systems. Am J Dent jun 1998(11):114-117.

De munk, Van Meerbeek, Yoshida Y, Inoue S, Vargas M,Suzuki K et al. Four year water degradation of total-etch adhesives bonded to dentin. J Dent Res 2003 (82):136-140.

Frankenberger R, Strobel WO, Lohbauer U, Krämer N, Petschelt A. The effect of six years of water storage on resin composite bonding to human dentin. J Biomed Mater Res B Appl Biomater 2004;69:25-32.

Nakabayashi N, Kojima K, Masuhara E. The promotion of adhesi on by the infiltration of monomersin to tooth substrates. J BiomedMater Res 1982;(16):265-273.

Tay FR, Pashley D. Have dentin adhesives become too hydrophilic? J Can Dent Assoc. Dec 2003 69(11):726-731.

Yiu CK, Hiroishi N, Chersoni S, Breschi L, Ferroni M, Prati C, et al. Single-bottle adhesives behave as permeable membranes after polimerisation. II. Defferential permeability reduction with na oxalate. J Dent May 2005.

Tay FR, Frankenberg R, Krejci I, Boullaguet S, Pashley DH, Carvalho RM et al. Single-bottle adhesives behave as permeable membranes after polymerization. I. in vivo.

Carvalho RM, Tay FR, Giannini M, Pashley DH, Effect of pre- and post-bonding hydration on bond strength to dentin. J Adhes Dent. Aug 2004(6):13-17.

Malacarne J, Carvalho RM, Goes MF, Svizero N, Pashley DV, Tay FR, et al. Water sorption/solubility of dental adhesive resins. Dent Mater. Nov 2006 22(10): 973-980

Sano H, Shono T, Takatsu T, Hosoda H. Microporous dentin zone beneath resin-impregnated layer. Oper Dent 1994(19):59-64.

Spencer P, Swafford JR. Unprotected protein at the dentin adhesive interface. Quintessence Int 1999(30):501–507.

Pashley EL, Zhang Y, Lockwood PE, Rueggeberg FA, Pashley DH. Effects of Hema on water evaporation from water-HEMA mixtures. Dent Mater 1998 (14):6-10.

Abdussamad JY, George TV, Sreenivasa BV. The effect of storage and air drying on solvent evaporation of three different one-bottle adhesive systems: a comparative in vitro study. J Int Oral Health 2012 Sept-Dec 4(3):35-44

Nihi FM, Fabre HS, Garcia G, Fernandes KB, Ferreira FB, Wang L. In Vitro Assessment of solvent evaporation from commercial adhesive systems compared to experimental systems. Braz Dent J 2009 20(5):396-402

Cardoso Pde C, Loguercio AD, Vieira LC, Baratieri LN, Reis A. Effect of prolonged application times on resin–dentin bond strengths. J Adhes Dent 2005 (7):143–9.

Abate PF, Rodrigues VI, Macchi RL. Evaporation of solvent in one-bottle adhesives. J. Dent. 2000 (28):437-440.

Cho BH, Dickens SH. Effects of the acetone content of single solution dentin bonding agents on the adhesive layer thickness and the microtensile bond strength. Dent Mater 2004 (20):107–15.

Jacobsen T, Soderholm KJ. Some effects of water on dentin bonding. Dent Mater. Mar;1995 11(2):132-136.

Landuyt KL, De Munk J, Snauwaert J, Coutinho E, Poiteuin A, Yoshida Y et al. Monomer-solvent phase separation in one-step self-etch adhesives. J. Dent. Res. 2005 84(2):183-188.

Klein-Júnior CA, Zander-Grande C, Amaral R, Stanislawczuk R, Garcia EJ, Baumhardt-Neto R, Meier MM, Loguercio AD, Reis A. Evaporating solvents with a warm air-stream: effects on adhesive layer properties and resin- dentin bond strengths. J Dent 2008; 36:618-625.

King NM, Tay FR, Pashley DH, Hashimoto M, Ito S, Brackett WW et al. Conversion of one-step to two-step self- etch adhesives for improved efficacy and extended application. Am. J. Dent. 2004 (17):134-144.

Hashimoto M, Sano H, Yoshida E, Hori M, Kaga M, Oguchi H et al. Effect of multiple adhesive coatings on dentin bonding. Oper.Dent. 2004, 29(4):416-423.

Breschi L, Cadenaro M, Antoniolli F, Sauro S, Biasotto M, Prati C, Tay FR, Di Lenarda R. Polymerization kinetics of dental adhesives cured with LED: correlation between extent of conversion and permeability. Dent Mater 2007; 23:1066-1072.

Pasquantonio G, Tay FR, Mazzoni A, Suppa P, Ruggeri A Jr, Falconi M, et al. Eletric device improves bonds of simplifield etch-and-rinse adhesives. Dent. Mat.Marc 2007(23):513-518.

Reis A, Pellizzaro A, Dal-Bianco K, Gomes OM, Patzlaff R, Loguercio AD. Impact of adhesive application to wet and dry dentin on long-term resin-dentin bond strengths. Operat. Dent. 2007 32(4):380-387.

Dal-Bianco K, Pellizzaro A, Patzlaft R, Bauer JR, Loguercio AD, Reis A. Effects of moisture degree and rubbing action on the immediate resin-dentin bond strength. Dent.Mat. Oct 2006(22):1150-1156.

Cardoso PC, Loguercio AD, Vieira LC, Baratieri LN, Reis A. Effect of prolonged application times on resin-dentin bon strengths. J. Adhes. Dent. 2005 (7):143-149.

El-Din AK, Abd El-Mohsen MM. Effect of changin gap plication times on adhesive system Bond strengths. Am J Dent 2002;(15):321-324.

Kanca J. Effect of prime dwell time on dentin Bond strength. Gen Dent 1998;(46):608-612.

Miyazaki M, Tsubota K, Onose H, Hinoura K. Influence of adhesive application duration on dentin bonds trengthof single-application bonding systems. Oper. Dent 2002;(27):278-283.

Schulz K.F., Altman D.G, Moher D, CONSORT Group, CONSORT 2010 statement: updated guide lines for reporting parallel group randomised trials, Int. J. Surg. 2011(9):672–677.

Loguercio A.D, Reis A, Barbosa N.A, Roulet J.F, Five-year double-blind randomized clinical evaluation of a resin-modified glassi onomer and a polyacid-modifiedresin in non carious cervical lesions, J. Adhes. Dent. 2003(5):323–332.

Swift Jr. EJ, Perdigão J, Heymann OH, Wilder Jr. AD, Bayne, SC , May KN Jr., J. R et al. Eighteen-month clinical evaluation of a fille dandun filled dentin adhesive, J. Dent. 2001 (29): 1–6.

Da Costa TR, Loguercio AD, Reis A, Effect fename lbevel on the clinical performance of resin compositeres torations placed in non-carious cervical lesions, J. Esthet. Restor. Dent. 2013 (25):346–356.

Cvar JF, Ryge G, Schmalz G, Reprint of criteria for the clinical evaluation of dental restoration materials, Clin. Oral Invest. 2005 (9):7–24.

Perdigão J, Carmo AR, Geraldeli S. Eighteen-month clinical evaluation of two dentin adhesive sapplie dondry VS moistdentin. J Adhes. Dent. 2005;(7):253–8.

Aw TC, Lepe X, Johnson GH, Mancl LA. A three-year clinical evaluation of two-bottle versus one-bottle dentin adhesives. J Am. Dent. Assoc. 2005;(136):311–322.

Gallo JR, Burgess JO, Ripps AH, et al. Three-year clinical evaluation of a compomerand a resin composite as class V. Filling materials. Oper.Dent.2005;(30):275–281.

Loguercio AD, Bittencourt DD, Baratieri LN, Reis A.?A 36-month evaluationof self-etchand etch-and-rinse adhesives in non-carious cervical lesions. J Am. Dent. Assoc. 2007;(138):507–14.

Reis A, Loguercio AD. A 36-month clinical evaluation of ethanol/water and acetone-based etch-and-rinse adhesives in non-carious cervical lesions. Oper.Dent. 2009;34:384–91.

Perdigão J, Dutra-Corrêa M, Saraceni CH, et al. Randomized clinical Trial of four adhesion strategies: 18-month results. Oper.Dent. 2012;(37):3–11.

Pocock SJ, The sizeof a clinical trial, in: Pocock S.J. Clinical Trials: A Practical Approach, John Wiley & Sons, Chinchester, 1983,123–141.

American Dental Association Councilon Scientific Affairs, Acceptance Program Guidelines: Dentinand Enamel Adhesive Materials, American Dental Association, Chicago, 2011–12.

Hickel R, Roulet JF, Bayne S, Heintze SD, Mjör IA, Peters M, et al. Recommendations for conducting controlled clinical studies of dental restorative materials. Science Committee Project 2/98-FDI World Dental Federation study design (Part I) andcriteria for evaluation (Part II) of direct and indirect restorations including onlays and partial crowns, J. Adhes. Dent. 2007(9):121–147.

Hickel R, Peschke A, Tyas M, Mjör I, Bayne S, Peters M, et al. FDI World Dental Federation – clinical criteria for thee valuation of direct and in direct restorations – up date and clinical examples, J. Adhes. Dent. 2010 (12):259–272.

Dalton Bittencourt, D, Ezecelevski IG, Reis A, Van Dijken, JW, Loguercio AD. An 18-months’ evaluation of self-etch and etch-rinse adhesive in non-carious cervical lesions, Acta Odontol. Scand. 2005 (63):173–178.

Hickel R, Roulet JF, Baynes S, Heintze SD, Mj?r IA, Peters M et al. Recommendations for condducting controlled cinical studies od dental restorative matirials. Clin. Oral. Invest. 2007;(11):5-13.

Tjaderhane, L., Larjava H, Sorsa T, Uitto VJ, Larmas M, Salo T. The activation and function of host matrix metalloproteinases in dentin matrix breakdown in caries lesions. J. Dent. Res. 1998 77(8):1622-1629

.Sulkala, M., Tervahartiala T, Sorsa T, Larmas M, Salo T, Tjaderhane L. Matrix metalloproteinase-8 (MMP-8) is the major collagenase in human dentin. Arch. Oral Biol. 2005;52(2):121-127.

Loguercio AD, Barroso LP, Grande RHM, Reis A. Comparison of intra- and intertooth resin–dentin bond strength variability. J Adhes Dent 2005;7:151–8.

Van Landuyt KL, Snauwaert J, De Munck J, Coutinho E, Poitevin A, Yoshida Y, et al. Origin of interfacial droplets with one-step adhesives. J Dent Res. 2007 Aug;86(8):739-744

Ito, S., Hashimoto M, Wadgaonkar B, Svizero N, Carvalho RM, YiuC et al. Effects of resin hydrophilicity on water sorption and changes in modulus of elasticity. Biomat. 2005;26(33):6449-6459.

Carvalho RM, Tay FR, Giannini M, Pashley DH. Effects of pre-and post-bonding hydration on bond strength to dentin. JAdhes Dent 2004;6:13–7.

Breschi, L., Mazzoni A, Ruggeri A, Cadenaro M, Di Lenarda R, De Stefano Dorigo E. Dental adhesion review: aging and stability of the bonded interface. Dent. Mater. 2008;24(1): 90-101

.Chersoni, S, Suppa P, Breschi L, Ferrari M, Tay FR, Pashley, DH, et al. Water movement in the hybrid layer after different dentin treatments. Dent. Mater. 2004;20(9):796-803.

Chersoni, S., Suppa P, Grandini S, Goracci C, Monticelli F, Yiu C, et al. In vivo and in vitro permeability of one-step self-etch adhesives. J Dent Res 2004 83(6): 459-464.

Hashimoto M., Ito S, Tay SF, Svizero NS, Sano H, Kaga M et al. Fluid movement across the resin-dentin interface during and after bonding. J Dent Res 2004 83(11): 843-848.

Hebling, J., Pashley DH, Tjaderhane L, Tay FR. Chlorhexidine arrests subclinical degradation of dentin hybrid layers in vivo."J Dent Res 2005 84(8): 741-746.

Brackett, WW., Tay FR, Brackett MG, Dib A, Sword R.J, Pashley, DH. The effect of chlorhexidine on dentin hybrid layers in vivo.Oper Dent 2007;32(2):107-111.

Carrilho, M. R., Geraldeli S, Tay F, de Goes MF, Carvalho R.M, Tjaderhane L et al In vivo preservation of the hybrid layer by chlorhexidine. J Dent Res. 2007;86(6):529-533.

Carrilho, M. R., Tay FR, Donnelly AM, Agee KA, Tjaderhane L, Mazzoni A, et al. Host-derived loss of dentin matrix stiffness associated with solubilization of collagen. J Biomed. Mater. Res. B Appl Biomater 2009;90(1):373-380.

De Munck, J., Van den Steen PE., Mine A, Van Landuyt KL, Poitevin A, Opdenakker G et al. Inhibition of enzymatic degradation of adhesive-dentin interfaces. J. Dent. Res. 2009;88(12): 1101-1106.

Zhou, J, Tan J, Chen L, Li D, Tan Y. The incorporation of chlorhexidine in a two-step self-etching adhesive preserves dentin bond in vitro. J. Dent. 2009;37(10): 807-812.

De Munck, J., Mine A., Van den Steen PE., Van Landuyt KL, Poitevin A., Opdenakker G. et al. Enzymatic degradation of adhesive-dentin interfaces produced by mild self-etch adhesives.Eur J Oral Sci 2010; 118(5): 494-501.

Abu Nawareg M, Elkassas D, Zidan A, Abuelenain D, Abu Haimed T, Hassan, AH, et al Is chlorhexidine-methacrylate as effective as chlorhexidine digluconate in preserving resin dentin interfaces? J. Dent. Feb.2016 45:7-13.

J. Perdigao, C. Kose, A.P. Mena-Serrano, E.A. De Paula, L.Y. Tay, A. Reis, AD Loguercio. A new universal simplified adhesive: 18-month clinical evaluation, Oper. Dent. 2014 (39):113–127.

A. Mena-Serrano, Kose C., De Paula EA., Tay LY., Reis A., Loguercio A.D.et al. A new universal simplified adhesive: 6-month clinical evaluation, J. Esthet. Restor. Dent. 2013(25):55–69.

A.D. Loguercio, E.A. de Paula, V. Hass, I. Luque-Martinez, A. Reis, J. Perdigao, A new universal simplified adhesive: 36-Month randomized double-blind clinical trial, J. Dent. 43 (2015) 1083–1092.

N.C. Lawson, A. Robles, C.C. Fu, C.P. Lin, K. Sawlani, J.O. Burgess, Two-year clinical trial of a universal adhesive in total-etch and self-etch mode in non-carious cervical lesions, J. Dent. 43 (2015) 1229–1234.

M. Peumans, J. De Munck, A. Mine, B. Van Meerbeek, Clinical effectiveness of contemporary adhesives for the restoration of non-carious cervical lesions. A sys- tematic review, Dent. Mater. 30 (2014) 1089–1103.

R. Hickel, K. Brushaver, N. Ilie, Repair of restorations–criteria for decision making and clinical recommendations, Dent. Mater. 29 (2013) 28–50.

Neo J, Chew CL, Yap A, Sidhu S. Clinical evaluation of tooth-colored materials in cervical lesions Am. J. Dent. 1996 9(1) 15-18

Türkün LS (2005) The clinical performance of one- and two- step self-etching adhesive systems at one year Journal of the American Dental Association 136(5) 656-664.

Loguercio AD, Mânica P, Ferneda F, Zander-Grande C, Amaral R, Stanislawczuk R et al. A randonized cllinical evolution of a one-and two-step self etch adhesive over 24 months. Opearat. Dent. 2010, 35(2):265-272.

Published

2020-08-31

How to Cite

Camargo, M. N., Almeida, L. de, Scheffer, R. F., Alpini, C. B., Loguercio, A. D., Hass, V., Naufel, F. S., & Paula, E. A. de. (2020). Efeito da aplicação prolongada do sistema adesivo convencional de 2 passos na qualidade de restaurações de resina composta em lesões cervicais não cariosas: Ensaio clínico controlado, randomizado, duplo cego / Effect of the extended time of application of the conventional two-step adhesive system on the longevity of composite resin restorations in non-carious cervical lesions: a double-blind randomized clinical trial. Brazilian Journal of Development, 6(8), 63791–63823. https://doi.org/10.34117/bjdv6n8-709

Issue

Section

Original Papers