Autotransfusion System (AutoLog IQ) use in liposuction: a retrospective case-control study

Authors

  • Leandro Costa Gontijo
  • Juliana Almeida Oliveira
  • Raphaela Gomes Mendes
  • Jeniffer Paula Padilha dos Santos
  • Stefania Ramos de Oliveira Morais
  • Pollyana Magalhães Gontijo

DOI:

https://doi.org/10.34119/bjhrv7n5-017

Keywords:

lipectomy, lipoabdominoplasty, blood transfusion, cosmetic techniques, plastic surgery procedures

Abstract

Justification: Liposuction represents 15.4% of all surgical procedures, with mortality rates of 0.38-0.55 per 1000 procedures. Blood loss and anemia are related to mortality and fluid replacement lowers hemoglobin drop. Objective: To perform a retrospective case-control study to evaluate the autotransfusion system (Autolog IQ) use in lipoplasty. Methodology: Patients’ from the Instituto Mineiro de Cirurgia Plástica (Belo Horizonte) who had surgery in July-August 2023 had their medical charts evaluated. In the intervention group, fat removal and collection, with posterior washing was process in the Autolog IQ. The Autolog IQ, through a centrifugation process, spares and collects viable red blood cells, enabling autotransfusion. R Studio was used for statistical analysis. Results: 36 patients were included, of which 19 (52.8%) used Autolog with median blood infusion of 1031.93ml (n=15). The Autolog group had higher aspirated volume (4881.58±2287.6ml, range: 2000-11600ml versus 3761.76ml±1344.38ml, range: 2000-6200ml) and body weight aspirated volume (6.78%±2.9%, range: 2.94%-11.88% versus 5.47%±1.77%, range: 3.47%-8.49%). No statistical significance was found in: surgery time (p=0.95); diuresis (p=0.19); Hemoglobin (p=0.19), platelets (p=0.46), serum iron (p=0.64), ferritin (p=0.9), and prothrombin response (p=0.54); pain scale (p=0.29), seroma (p=0.89) and its volume (p=0.07); necrosis and thrombophlebitis (p=0.31); dehiscence (p=0.26); epidermolysis and infection (p=0.45). There was no statistical significance in subgroups analysis. Conclusion: No statistical difference was observed between the groups for clinical and laboratory outcomes. The difference in aspirated volume between groups may have increased heterogeneity.

References

ISAPS International Survey on Aesthetic/cosmetic procedures, performed in 2022. International Society of Aesthetics Plastic Surgery; Available at: https://www.isaps.org/media/a0qfm4h3/isaps-global-survey_2022.pdf. Accessed December 8, 2023.

Barros LFL, Teixeira VF, Reis Júnior JAP, Ferraz RA, Araújo DDC, Vendramin FS. Complications in liposuction: systematic review. Braz J Plast Sugery. 2023;38(1).

Sozer SO, Basaran K, Alim H. Abdominoplasty with Circumferential Liposuction: A Review of 1000 Consecutive Cases. Plast Reconstr Surg. 2018 Oct;142(4):891–901.

Montrief T, Bornstein K, Ramzy M, Koyfman A, Long B. Plastic Surgery Complications: A Review for Emergency Clinicians. West J Emerg Med. 2020 Sep 25;21(6).

Campos R, Soley NAR, Campos BVBL. Patient safety: changes in hemoglobin and serum iron after liposuction and/or abdominoplasty. Braz J Plast Sugery. 2018;33(4):511–7.

Mandel MA. Blood and fluid replacement in major liposuction procedures. Aesthet Plast Surg. 1990; 14(3):187-91.

American Society of Plastic Surgeons. Liposuction - Lipoplasty. Available at: https://www.plasticsurgery.org/cosmetic-procedures/liposuction. Accessed December 8, 2023.

Australian Society of Plastic Surgeons. Liposuction. Available at: https://plasticsurgery.org.au/procedures/surgical-procedures/liposuction/. Accessed December 8, 2023.

Brazilian Society of Plastic Surgery. Lipoaspiração - Cirurgias e Procedimentos. Available at: http://www2.cirurgiaplastica.org.br/cirurgias-e-procedimentos/lipoaspiracao. Accessed December 8, 2023.

Karmo F, Milan M, Stein S, Heinsimer J. Blood loss in major lipoplasty procedures with the tumescent technique. Aesthet Surg J. 1998;18(1):30–5.

Geiger P, Platow K, Barti A, Volk C, Junker K, Mehrkens H. New developments in autologous transfusion systems. Anaesthesia. 1998;53(2).

Meybohm P, Choorapoikayil S, Wessels A, Herrmann E, Zacharowski K, Spahn DR. Washed cell salvage in surgical patients: A review and meta-analysis of prospective randomized trials under PRISMA. Medicine (Baltimore). 2016 Aug;95(31):e4490.

Hannon T. Medtronic autoLog® Autotransfusion System: Comparative Wash Quality and Clinical Assessment. Techinal Concept Paper published my Medtronic. 1999.

Serrick CJ, Scholz M, Melo A, Singh O, Noel D. Quality of Red Blood Cells Using Autotransfusion Devices: A Comparative Analysis. J Extracorpor Technol. 2003 Mar;35(1):28–34.

Vieira BL, Chow I, Sinno S, Dorfman RG, Hanwright P, Gutowski KA. Is There a Limit? A Risk Assessment Model of Liposuction and Lipoaspirate Volume on Complications in Abdominoplasty. Plast Reconstr Surg. 2018 Apr;141(4):892–901.

Restifo RJ. Sub-Scarpa’s Lipectomy in Abdominoplasty: An Analysis of Risks and Rewards in 723 Consecutive Patients. Aesthet Surg J. 2019 Aug 22;39(9):966–76.

Xia Y, Zhao J, Cao DS. Safety of Lipoabdominoplasty Versus Abdominoplasty: A Systematic Review and Meta-analysis. Aesthetic Plast Surg. 2019 Feb;43(1):167–74.

Wu S, Coombs DM, Gurunian R. Liposuction: Concepts, safety, and techniques in body-contouring surgery. Cleve Clin J Med. 2020 Jun;87(6):367–75.

Husain TM, Salgado CJ, Mundra LS, Perez C, AlQattan HT, Bustillo E, et al. Abdominal Etching: Surgical Technique and Outcomes. Plast Reconstr Surg. 2019 Apr;143(4):1051–60.

Downloads

Published

09/02/2024

How to Cite

GONTIJO, L. C.; OLIVEIRA, J. A.; MENDES, R. G.; SANTOS, J. P. P. dos; MORAIS, S. R. de O.; GONTIJO, P. M. Autotransfusion System (AutoLog IQ) use in liposuction: a retrospective case-control study. Brazilian Journal of Health Review, [S. l.], v. 7, n. 5, p. e72453, 2024. DOI: 10.34119/bjhrv7n5-017. Disponível em: https://ojs.brazilianjournals.com.br/ojs/index.php/BJHR/article/view/72453. Acesso em: 17 oct. 2026.

Issue

Section

Original Papers